期刊
INDOOR AIR
卷 15, 期 5, 页码 356-362出版社
WILEY
DOI: 10.1111/j.1600-0668.2005.00381.x
关键词
allergen; day-care center; endotoxin; house dust; indoor environment; school
Allergy to indoor allergens can cause frequent and severe health problems in children. Because little is known about the content of allergens in the indoor environments in Norway, we wanted to assess the levels of cat, dog and mite allergens in schools and day-care centers in Oslo. Allergen levels in dust samples from 155 classrooms and 81 day-care units were measured using commercially available enzyme-linked immunosorbent assay (ELISA) kits. Additionally, we measured the levels of endotoxin in 31 day-care units, using the limulus amebocyte lysate test. Most of the dust samples contained detectable amounts of cat and dog allergens. In mattress and floor dust (day-care centers), and curtain and floor dust (schools) the median Fel d 1 levels were 0.17, 0.002, 0.02 and 0.079 mu g/m(2), while the median Can f 1 levels were 1.7, 0.03, 0.1 and 0.69 mu g/m(2), respectively. Levels of cat and dog allergens in school floor dust were associated with the number of pupils with animals at home. In contrast, < 1% of the samples had measurable levels of the mite allergen Der p 1. Moreover, the levels of endotoxin tended to be higher in dust from floors (1.4 ng/m(2)) compared with that from mattresses (0.9 ng/m(2)).
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐