期刊
RADIOLOGY
卷 237, 期 1, 页码 316-321出版社
RADIOLOGICAL SOC NORTH AMERICA
DOI: 10.1148/radiol.2371040830
关键词
-
This study had institutional review board approval, and all patients gave informed consent. The purpose of this study was to prospectively evaluate the use of whole-heart three-dimensional (3D) coronary magnetic resonance (MR) angiography in patients suspected of having coronary artery disease. Whole-heart coronary MR angiography was performed in 39 patients (30 men and nine women; mean age, 63.9 years +/- 15.6 [standard deviation]) by using a steady-state free precession sequence with free breathing. Twenty patients (16 men and four women; mean age, 64.9 years +/- 11. 7) also underwent conventional coronary angiography. MR angiography was successfully completed in 34 of 39 patients (87%); the average imaging time was 13.8 minutes +/- 3.8. Sensitivity and specificity of MR angiography for detecting significant stenosis were 82% (14 of 17 arteries) and 91% (39 of 43 arteries), respectively. Whole-heart coronary MR angiography with a navigator-gated steady-state sequence can enable reliable 3D visualization of the coronary arteries in patients suspected of having coronary artery disease. (c) RSNA, 2005.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐