4.7 Article

Stratospheric and tropospheric NO2 variability on the diurnal and annual scale:: a combined retrieval from ENVISAT/SCIAMACHY and solar FTIR at the Permanent Ground-Truthing Facility Zugspitze/Garmisch

期刊

ATMOSPHERIC CHEMISTRY AND PHYSICS
卷 5, 期 -, 页码 2657-2677

出版社

COPERNICUS GESELLSCHAFT MBH
DOI: 10.5194/acp-5-2657-2005

关键词

-

向作者/读者索取更多资源

Columnar NO2 retrievals from solar FTIR measurements at the Zugspitze (47.42 degrees N, 10.98 degrees E, 2964 m a. s. l.), Germany were investigated synergistically with columnar NO2 retrieved from SCIAMACHY data by the University of Bremen scientific algorithm UB1.5 for the time span July 2002 - October 2004. A new concept to match FTIR data to the time of satellite overpass makes use of the NO2 daytime increasing rate retrieved from the FTIR data set itself [+ 1.02(6) E+ 14 cm(-2)/ h]. This measured increasing rate shows no significant seasonal variation. SCIAMACHY data within a 200-km radius around Zugspitze were considered, and a pollution-clearing scheme was developed to select only pixels corresponding to clean background ( free) tropospheric conditions, and exclude local pollution hot spots. The resulting difference between SCIAMACHY and FTIR columns ( without correcting for the different sensitivities of the instruments) varies between 0.60 - 1.24 E+ 15 cm(-2) with an average of 0.83 E+ 15 cm(-2). A day-to-day scatter of daily means of approximate to 7-10% could be retrieved in mutual agreement from FTIR and SCIAMACHY. Both data sets are showing sufficient precisions to make this assessment. Analysis of the averaging kernels gives proof that at high-mountain-site FTIR is a highly accurate measure for the pure stratospheric column, while SCIAMACHY shows significant tropospheric sensitivity. Based on this finding, we set up a combined a posteriori FTIR-SCIAMACHY retrieval for tropospheric NO2, based upon the averaging kernels. It yields an annual cycle of the clean background ( free) tropospheric column (< 10 km) with variations between 0.75 - 1.54 E+ 15 cm(-2), an average of 1.09 E+ 15 cm(-2), and an intermediate phase between that of the well known boundary layer and stratospheric annual cycles. The outcome is a concept for an integrated global observing system for tropospheric NO2 that comprises DOAS nadir satellite measurements and a set of latitudinally distributed mountain-site or clean-air FTIR stations.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据