4.6 Article

Experimental investigation of vitreous humour motion within a human eye model

期刊

PHYSICS IN MEDICINE AND BIOLOGY
卷 50, 期 19, 页码 4729-4743

出版社

IOP PUBLISHING LTD
DOI: 10.1088/0031-9155/50/19/021

关键词

-

向作者/读者索取更多资源

We present an experimental study of the vitreous motion induced by saccadic eye movements. A magnified model of the vitreous chamber has been employed, consisting of a spherical cavity carved in a perspex cylindrical container, which is able to rotate with a prescribed time law. Care has been taken to correctly reproduce real saccadic eye movements. The spherical cavity is filled with glycerol and the flow field is measured on the equatorial plane orthogonal to the axis of rotation, through the PIV technique. Visualizations of the fully three-dimensional flow suggest that it essentially occurs on planes perpendicular to the axis of rotation, the motion orthogonal to such planes being smaller by three to four orders of magnitude. Theoretical results, based on a simplified solution, are in very good agreement with the experimental findings. The maximum value of the shear stress at the wall, which is thought to play a possibly important role in the pathogenesis of retinal detachment, does not significantly depend on the amplitude of saccadic movements. This suggests that relatively small eye rotations, being much more frequent than large movements, are mainly responsible for vitreous stresses on the retina. Results also illustrate the dependence of the maximum shear stress at the wall from the vitreous viscosity.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据