Measuring microlymphatic flow using fast video microscopy -: art. no. 064016

期刊

JOURNAL OF BIOMEDICAL OPTICS
卷 10, 期 6, 页码 -

出版社

SPIE-INT SOCIETY OPTICAL ENGINEERING
DOI: 10.1117/1.2135791

关键词

lymphatics; velocity; video microscopy

资金

  1. NHLBI NIH HHS [R01 HL070308-03, HL-070308, R01 HL070308] Funding Source: Medline

向作者/读者索取更多资源

Despite advances in the measurement of lymphatic function, little is known about the actual velocities of flow in microlymphatic (similar to 100 mu m diam) vessels. In this work, video microscopy and particle tracking methods are adapted and integrated with an ultra-highspeed imaging camera to obtain measurements of lymph velocities throughout the entire lymphatic contraction cycle in the rat mesentery, something that previous systems were incapable of measuring. To determine the system's accuracy, calibration experiments are conducted across the hypothesized physiologically significant range of velocities for microlymphatic flow (up to 15 mm/sec). The system shows high accuracy, less than 2% error, when comparing actual with measured velocities. Microspheres flowing through 140-mu m-diam tubing are imaged to demonstrate the system's ability to determine flow rates in these small vessels by measuring particle velocities. To demonstrate biological applicability, mesenteric microlymphatics in loops of the small intestine of three male Sprague-Dawley rats are exteriorized and imaged with the high-speed system at a rate of 500 frames/sec for several contraction sequences. Lymph velocity fluctuates cyclically with the vessel wall contractions, ranging from -1 to 7 mm/sec. These rates are higher than would be possible with standard video microscopy (3.75 mm/sec maximum). (C) 2005 Society of Photo-Optical Instrumentation Engineers.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据