4.7 Article

Computer-aided diagnosis of localized ground-glass opacity in the lung at CT: Initial experience

期刊

RADIOLOGY
卷 237, 期 2, 页码 657-661

出版社

RADIOLOGICAL SOC NORTH AMERICA
DOI: 10.1148/radiol.2372041461

关键词

-

向作者/读者索取更多资源

The purpose of this study was to: develop an automated scheme to, facilitate detection of localized ground-glass opacity (GGO) in the, lung at computed tomography, (CT). Institutional review board approval and informed consent,we I re not required. Two radiologists reviewed CT images from 14 patients (five men, nine women) who had lung cancer or metastasis and whose malignancy was classified as GGO. The lung region was sampled and completely covered with contiguous 50% overlapping regions of interest (ROIs) measuring 30 X 30 pixels in size. The lung area within each ROI was analyzed to compute texture features and gaussian curve fitting features. Performance of the artificial, neural networks (ANNs) measured by using the area under the receiver, operating characteristic curve was 0.92. With a threshold of 0.9, the sensitivity of the ANN for detecting, GGO ROIs was 94.3% (280 of 297 ROIs), and the positive predictive value was 29.1% (280 of 963 ROIs)., A computerized scheme may hold promise in facilitating detection of localized GGO at CT. (c) RSNA, 2005.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据