3.8 Article

Elevated Sound Levels within a Busy NICU

期刊

NEONATAL NETWORK
卷 24, 期 6, 页码 33-37

出版社

SPRINGER PUBLISHING CO
DOI: 10.1891/0730-0832.24.6.33

关键词

-

类别

资金

  1. National Institutes of Health, Institute of Nursing Research [NIH/NINR P20 NR07791, NIH/NCRR MO1 RR00082]

向作者/读者索取更多资源

Purpose: Elevated sound levels in the NICU may contribute to undesirable physiologic and behavioral effects in preterm infants. This study describes sound levels in a busy NICU in the southeastern U.S. and compares the findings with recommended NICE noise level standards. Design: NICU sound levels were recorded continuously at nine different locations within the NICU. Hourly measurements of loudness equivalent (Leq) sound level, sound level exceeded 10 percent of the time (L-10), and maximum sound level (Lmax) were determined. Sample: Sound levels were sampled from nine different locations within the NICU. Main Outcome Variable: Sound levels are described using the hourly, A-weighted Leq, L-10, and Lmax. Results: The overall average hourly Leq (M = 60.44 dB, range = 55-68 dB), L-10 (M = 59.26 dB, range = 55-66 dB), and Lmax (M = 78.39, range = 69-93 dB) were often above the recommended sound levels (hourly Leq <50 dB, L-10 <55 dB, and 1-second Lmax <70 dB). In addition, certain times of day, such as 6-7 AM and 10 AM-12 noon, were noisier than other times of day.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

3.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据