关键词

tuned liquid column damper; mass ratio; frequency tuning ratio; head loss coefficient; shake table test

向作者/读者索取更多资源

In this paper, some useful guidelines for designing tuned liquid column dampers (TLCDs) for damped single-degree-of-freedom structures under a white noise type of wind excitation are proposed as quick guidance for industrial practice. These guidelines contain two major parts that serve two respective purposes. One is the design table that provides the list of necessary optimal parameters as well as the corresponding response reduction to be used as the design reference. The other is the empirical formula for reliably predicting the basic properties of TLCDs, especially for head loss coefficients, to ensure the design objectives can be achieved. In the first part, the solutions of optimal parameters in the design table are obtained through numerical optimization, by which it is also found that for a given mass ratio and horizontal length ratio, using a uniform cross-section for all columns can always achieve the best performance. To construct the prediction formula in the second part, TLCD property tests using free vibration and harmonic forced vibration techniques via a shake table are performed and the experimental results thus calibrated are used. Consequently, a modified formula to predict head loss coefficients for TLCDs with sharp-edged elbows is proposed as a guideline for designers. Finally, an example of the TLCD design is demonstrated by following the guidelines presented. (c) 2005 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据