期刊
JOURNAL OF ARTHROPLASTY
卷 20, 期 8, 页码 998-1001出版社
CHURCHILL LIVINGSTONE INC MEDICAL PUBLISHERS
DOI: 10.1016/j.arth.2005.01.020
关键词
failed metal-backed patellar component; all-polyethylene patellar component; isolated patellar revision
类别
Several reports document high failure rates of metal-backed patellar components, but few report the outcome of revising these components to all-polyethylene, cemented implants. At a mean 87.2-month follow-up, we describe a series of 36 patients (40 knees) who underwent isolated metal-backed patellar revision to a cemented, all-polyethylene patellar component. After the patellar revision, 5 patients (6 knees) underwent additional surgery, but no patellar components required revision. The additional surgeries were performed at an average of 77.6 months after patellar revision and included 3 tibial insert exchanges for polyethylene wear, 2 revisions of femoral and tibial components for osteolysis, and 1 realignment procedure for recurrent subluxation of the patella. We conclude that revision of a failed metal-backed patellar component to a cemented, all-polyethylene patella is a durable, successful procedure.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐