Measurement of strain in the left ventricle during diastole with cine-MRI and deformable image registration

出版社

ASME
DOI: 10.1115/1.2073677

关键词

strain; left ventricle; deformable image registration; soft tissue mechanics; finite element; magnetic resonance imaging

资金

  1. NIBIB NIH HHS [R01-EB00121] Funding Source: Medline

向作者/读者索取更多资源

The assessment of regional heart wall motion (local strain) can localize ischemic myocordial disease, evaluate myocardial viability, and idently impaired cardiac function due to hypertrophic or dilated cardiomyopathies. The objectives of this research were to develop and validate a technique known as hyperelastic warping for the measurement of local strains in the left ventricle from clinical cine-magnetic resonance imaging (MRI) image datasets. The technique uses differences in image intensities between template (reference) and target (loaded) image datasets to generate a body force that deforms a finite element (FE) representation of the template so that it registers with the target image. To validate the technique, MRI image datasets representing two deformation states of a left ventricle were created such that the deformation map between the states represented in the images was known. A beginning diastolic cine-MRI image dataset from a normal human subject was defined as the template. A second image dataset (target) was created by mapping the template image using the deformation results obtained from a,forward FE model of diastolic filling. Fiber stretch and strain predictions from hyperelastic warping showed good agreement with those of the forward solution (R-2 = 0.67 stretch, R-2 = 0.76 circunifcrential strain, R-2 = 0.75 radial strain, and R-2 = 0.70 in-plane shear). The technique had low sensitivity to changes in material parameters (Delta R-2 = -0.023 fiber stretch, Delta R-2 = -0.020 circumferential strain, Delta R-2 = -0.005 radial strain, and Delta R-2 = 0.0125 shear strain with little or no change in rms error), with the exception of changes in bulk modulus of the material. The use of an isotropic hyperelastic constitutive model in the warping analyses degraded the predictions of fiber stretch. Results were unaffected by simulated noise down to a signal-to-noise ratio (SNR) of 4.0 (Delta R-2 = -0.032 fiber stretch, Delta R-2 = -0.023 circumferential strain, Delta R-2 = -0.04 radial strain, and Delta R-2 = 0.0211 shear strain with little or no increase in rms error). This study demonstrates that warping in conjunction with cine-MRI imaging can be used to determine local ventricular strains during diastole.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据