期刊
MICROWAVE AND OPTICAL TECHNOLOGY LETTERS
卷 47, 期 6, 页码 546-548出版社
JOHN WILEY & SONS INC
DOI: 10.1002/mop.21226
关键词
antenna-coupled detectors; microbolometers; silicon nitride membrane; responsivity; thermal impedance
Square-spiral antenna-coupled microbolometers made of gold and chrome are fabricated on a silicon-nitride membrane. The membrane gives mechanical stability and thermal isolation to the detectors so that they can be used as picture elements in commercial infrared-imaging systems. The fabricated devices are measured under room pressure and tinder vacuum, giving D* values of 3 X 10(6) cm root Hz/W and 1.7 X 10(7) cm root Hz/W, respectively. By using vanadium-oxide, values well above 1 X 10(8) cm root Hz/W for D* can be obtained. Variations to the fabrication process that will allow the use of vanadium oxide are suggested. (c) 2005 Wiley Periodicals, Inc.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。