4.6 Article

Intrinsically radiopaque iodine-containing polyvinyl alcohol as a liquid embolic agent:: evaluation in experimental wide-necked aneurysms

期刊

JOURNAL OF NEUROSURGERY
卷 104, 期 2, 页码 290-297

出版社

AMER ASSOC NEUROLOGICAL SURGEONS
DOI: 10.3171/jns.2006.104.2.290

关键词

experimental aneurysm; liquid embolic agent; iodine-containing polyvinyl alcohol; swine

向作者/读者索取更多资源

Object. To evaluate iodine-containing polyvinyl alcohol (I-PVA) as a precipitating liquid embolic agent, implant characteristics-including radiopacity, setting behavior, and biocompatibility-were studied in an aneurysm model in swine. Methods. Twelve broad-based carotid artery (CA) sidewall aneurysms were surgically constructed in six pigs. Iodine-containing polyvinyl alcohol dissolved in dimethyl sulfoxide (DMSO) was injected during temporary balloon occlusion bridging the aneurysm neck. Control angiography as well as multidetector row computerized tomography (CT) angiography was performed after 4 weeks. Harvested aneurysms were investigated histopathologically and by 3-tes-1a high-field magnetic resonance (MR) imaging. The mean degree of aneurysm occlusion achieved was 96%. In two aneurysms a minimal protrusion of I-PVA into the CA lumen was observed. During one embolization, leakage of the liquid embolic agent due to DMSO-induced damage of the microcatheter resulted in CA occlusion. Aneurysms embolized with I-PVA could be discriminated clearly from the parent artery on CT angiograms because there was no beam-hardening artifact. High-field MR imaging allowed a detailed depiction of the liquid embolic distribution within the aneurysm. Histologically, a mild to moderate inflammatory response was found in successfully embolized aneurysms, and the polymer mass was frequently covered by a membrane of fibroblasts and endothelial cells. Conclusions. Iodine-containing polyvinyl alcohol is a ready-to-use liquid embolic agent clearly visible under fluoroscopy; additives are not required. The setting behavior allows for controlled delivery in aneurysm cavities. Histological studies performed 4 weeks after embolization revealed no sign of toxic tissue response to the liquid embolic agent. Overall, I-PVA exhibits interesting implant characteristics in that radiopaque admixtures are not necessary, thus allowing for artifact-free evaluation of treated aneurysms by using CT and MR angiography.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据