4.7 Article

Determining the contact angle between liquids and cylindrical surfaces

期刊

JOURNAL OF COLLOID AND INTERFACE SCIENCE
卷 294, 期 2, 页码 418-422

出版社

ACADEMIC PRESS INC ELSEVIER SCIENCE
DOI: 10.1016/j.jcis.2005.07.025

关键词

adhesion work; biocompatibility; contact angle measurement; cylindrical surfaces; liquid-solid interface

向作者/读者索取更多资源

One of the simplest methods of measuring the quantities for estimating the adhesion properties of materials (i.e., the adhesion work, the surface energy, and the interfacial tension between certain liquids and a surface) requires the determination of the contact angle between the liquid and the surface. In the case of plane surfaces the determination of the drop dimensions makes it possible to calculate the contact angle by the sessile drop method, but in the case of cylindrical surfaces (such as the monotilaments), several methods were developed to improve the accuracy of the contact angle measurements. This paper presents a comprehensive method for precise evaluation of the contact angle between liquid drops and monotilaments by establishing a differential equation describing the drop contour. This equation makes it possible to accurately compute the contact angle using the dimensions of the drop. A comparison of the values of the contact angle calculated by our method and those obtained by other approaches is made. We applied our method in the case of polyamide-6 monofilaments treated using dielectric barrier discharge, knowing their medical applications in surgical sutures. (c) 2005 Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据