4.5 Article

Sham device versus inert pill: randomised controlled trial of two placebo treatments

期刊

BMJ-BRITISH MEDICAL JOURNAL
卷 332, 期 7538, 页码 391-394

出版社

BMJ PUBLISHING GROUP
DOI: 10.1136/bmj.38726.603310.55

关键词

-

向作者/读者索取更多资源

Objective To investigate whether a sham device (a validated sham acupuncture needle) has a greater placebo effect than all inert pill in patients with persistent arm pain. Design A single blind randomised controlled trial created from the two week placebo run-in periods for two nested trials that compared acupuncture and amitriptyline with their respective placebo controls. Comparison of participants who remained oil placebo continued beyond the run-in period to the end of the Study. Setting Academic medical centre. Participants 270 adults with arm pain due to repetitive use that had lasted at least three months despite treatment and who scored ! 3 oil a 10 point pain scale. Interventions Acupuncture with sham device twice a week for six weeks or placebo pill once a day for eight weeks. Main outcome measures Arm pain measured oil a 10 point pain scale. Secondary Outcomes were symptoms measured by the Levine symptom severity scale, function measured by Pransky's upper extremity function scale, and grip strength. Results Pain decreased during the two week placebo run-in period in both the sham device and placebo pill groups, but changes were not different between the groups (- 0.14, 95% confidence interval - 0.52 to 0.25, P = 0.49). Changes in severity scores for arm symptoms and grip strength were similar between groups, but arm function improved more in the placebo pill group (2.0, 0.06 to 3.92, P = 0.04). Longitudinal regression analyses that followed participants throughout the treatment period showed significantly greater downward slopes per week oil the 10 point arm pain scale in the sham device group than in the placebo pill group (- 0.33 (- 0.40 to - 0.26) v - 0.15 (- 0.2 t to 0.09), P = 0.0001) and oil the symptom severity scale (- 0.07 (- 0.09 to - 0.05) v - 0.05 (- 0.06 to - 0.03), P 0.02). Differences were not significant, however, oil the function scale or for g-rip strength. Reported adverse effects were different in the two groups. Conclusions The sham device had greater effects than the placebo pill on self reported pain and severity of symptoms over the entire course of treatment but not during the two week placebo run ill. Placebo effects seem to be malleable and depend oil the behaviours embedded in medical rituals.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据