4.5 Article

Protocol for measurement of liver fat by computed tomography

期刊

JOURNAL OF APPLIED PHYSIOLOGY
卷 100, 期 3, 页码 864-868

出版社

AMER PHYSIOLOGICAL SOC
DOI: 10.1152/japplphysiol.00986.2005

关键词

liver attenuation; spleen; fatty liver; hepatic steatosis

资金

  1. NIA NIH HHS [AG-06945] Funding Source: Medline

向作者/读者索取更多资源

To develop a protocol for measurement of liver fat using computed tomography (CT), we conducted a preliminary study with 118 men and 76 women to determine a readily identifiable vertebral landmark at which the CT image displayed both liver and spleen. Analysis of five landmarks revealed that the CT image obtained at the T-12-L-1 level simultaneously displayed the liver and spleen in 90% of the men and women. The T-12-L-1 protocol was cross-validated on a sample of 130 men and 113 women. In this sample, we also assessed the regional characteristics of liver and spleen tissue attenuation at the T-12-L-1 level by subdividing each image into quartiles from anterior to posterior, each of which were further divided into medial and lateral regions. A similar analysis was performed on images located 12 mm above and below T-12-L-1. The T-12-L-1 image displayed both liver and spleen in 92% (403 of 437) of the combined study sample. There was a significant (P < 0.005) stepwise increase in attenuation values [Hounsfield units (HU)] from the inferior to superior image. Although some significant (P < 0.05) differences were observed between the eight regions by comparison to the whole liver or spleen, the average magnitude of the difference was < 2.0 HU for liver and < 3.5 HU for spleen. Acquisition of a single CT image at the T-12-L-1 level is a practical and reliable method for routine measurement of liver fat in research and clinical settings.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据