期刊
REVIEW OF SCIENTIFIC INSTRUMENTS
卷 77, 期 3, 页码 -出版社
AMER INST PHYSICS
DOI: 10.1063/1.2165271
关键词
-
Efficient primary ion sources at ISOL facilities normally produce singly charged ions. This limits the usable mass range for postacceleration due to the A IQ acceptance of the accelerator. At the ISAC facility at TRIUMF an A/Q below 7 is desired to avoid further stripping. Thus, charge state breeding is necessary if higher masses are to be accelerated. A 14 GHz ECRIS PHOENIX booster has been chosen as a breeder. In order to investigate and optimize its performance under ISAC conditions it has been set up at a test bench equipped with a standard ISAC target-ion-source to produce singly charged ions. A series of measurements has been performed with the noble gases Ar, Kr, and Xe. Efficiencies of more than 6% in the maximum of the charge state distribution after mass separation have been obtained and the emittance of the extracted beam and breeding times have been measured. This article gives a status report on the ongoing measurements. (c) 2006 American Institute of Physics.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据