4.6 Article

Comparison of results of ATP bioluminescence and traditional hygiene swabbing methods for the determination of surface cleanliness at a hospital kitchen

出版社

ELSEVIER GMBH, URBAN & FISCHER VERLAG
DOI: 10.1016/j.ijheh.2005.09.007

关键词

ATP bioluminescence; surface cleanliness; hygiene swabbing

向作者/读者索取更多资源

Adenosine triphosphate (ATP) bioluminescence and traditional microbiological swabbing culture methods were used for detection of surface hygiene oil worktops, cutting boards and equipments at a hospital kitchen. A total of 280 surface samples were collected from the kitchen. The agreement between the two methods (coefficient of Kappa) was statistically significant (corrected chi(2) = 30.886; kappa = 0.249; p<0.001). Consequently, the ATP monitoring method provides results rapidly with improved benefits in the control of surface contamination and application of corrective action against poor hygiene. However, it is not a substitute for culturing methods, the combination of both methods was emphasized for surface hygiene monitoring. Besides, the results indicate that., for food safety and public health, the hygienic status of the surfaces in the kitchen should be improved and food handlers should be trained well on hygiene. (C) 2005 Elsevier GmbH. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据