期刊
SENSORS AND ACTUATORS A-PHYSICAL
卷 127, 期 2, 页码 366-380出版社
ELSEVIER SCIENCE SA
DOI: 10.1016/j.sna.2005.12.045
关键词
micro-structure; Galerkin method; pull-in; beam; plate; one-mode analysis; multi-mode analysis
The one-mode analysis method on the pull-in instability of micro-structure under electrostatic loading is presented. Taylor series are used to expand the electrostatic loading term in the one-mode analysis method, which makes analytical solution available. The one-mode analysis is the combination of Galerkin method and Cardan solution of cubic equation. The one-mode analysis offers a direct computation method on the pull-in voltage and displacement. In low axial loading range, it shows little difference with the established multi-mode analysis on predicting the pull-in voltages for three different structures (cantilever, clamped-clamped beams and the plate with four edges simply-supported) studied here. For numerical multi-mode analysis, we also show that using the structural symmetry to select the symmetric mode can greatly reduce both the computation effort and the numerical fluctuation. (c) 2006 Elsevier B.V. All rights reserved.