4.7 Article

Sirolimus-eluting stents vs vascular brachytherapy for in-stent restenosis within bare-metal stents - The SISR randomized trial

期刊

JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION
卷 295, 期 11, 页码 1264-1273

出版社

AMER MEDICAL ASSOC
DOI: 10.1001/jama.295.11.1264

关键词

-

向作者/读者索取更多资源

Context Although vascular brachytherapy is the only approved therapy for restenosis following bare-metal stent implantation, drug-eluting stents are now being used. Data on the relative merits of each are limited. Objective To determine the safety and efficacy of the sirolimus-eluting stent compared with vascular brachytherapy for the treatment of patients with restenosis within a bare-metal stent. Design, Setting, and Patients Prospective, multicenter, randomized trial of 384 patients with in-stent restenosis who were enrolled between February 2003 and July 2004 at 26 academic and community medical centers. Data presented represent all follow-up as of June 30, 2005. Interventions Vascular brachytherapy (n = 125) or the sirolimus-eluting stent (n = 259). Main Outcome Measure Target vessel failure (cardiac death, myocardial infarction, or target vessel revascularization) at 9 months postprocedure. Results Baseline patient characteristics were well matched. Lesion length was similar between vascular brachytherapy and sirolimus-eluting stent patients (mean [SD], 16.76 [8.55] mm vs 17.22 [7.97] mm, respectively; P = .61). Procedural success was 99.2% (124/125) in the vascular brachytherapy group and 97.3% (250/257) in the sirolimus-eluting stent group (P = .28). The rate of target vessel failure was 21.6% (27/125) with vascular brachytherapy and 12.4% (32/259) with the sirolimus-eluting stent (relative risk [RR], 1.7; 95% confidence interval [CI], 1.1-2.8; P = .02). Target lesion revascularization was required in 19.2% (24/125) of the vascular brachytherapy group and 8.5% (22/259) of the sirolimus-eluting stent group (RR, 2.3 [ 95% CI, 1.3-3.9]; P = .004). At follow-up angiography, the rate of binary angiographic restenosis for the analysis segment was 29.5% (31/105) for the vascular brachytherapy group and 19.8% (45/227) for the sirolimus-eluting stent group (RR, 1.5 [ 95% CI, 1.0-2.2]; P = .07). Compared with the vascular brachytherapy group, minimal lumen diameter was larger in the sirolimus-eluting stent group at 6-month follow-up (mean [ SD], 1.52 [0.63] mm vs 1.80 [ 0.63] mm; P < .001), reflecting greater net lumen gain in the analysis segment (0.68 [0.60] vs 1.0 [0.61] mm; P < .001) due to stenting and no edge restenosis. Conclusion Sirolimus-eluting stents result in superior clinical and angiographic outcomes compared with vascular brachytherapy for the treatment of restenosis within a bare-metal stent.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据