4.7 Article

Breast microcallcifications: Retrieval failure at prone stereotactic core and vacuum breast biopsy - Frequency, causes, and outcome

期刊

RADIOLOGY
卷 239, 期 1, 页码 61-70

出版社

RADIOLOGICAL SOC NORTH AMERICA
DOI: 10.1148/radiol.2383041953

关键词

-

向作者/读者索取更多资源

Purpose: To retrospectively determine the frequency and causes or failure to retrieve microcalcifications in nonpalpable lesions, as judged on a radiograph or the specimen, and to determine outcome in patients with those lesions. Materials and Methods: Informed consent was obtained from each patient prior to biopsy. The institutional review board approved this HIPAA-compliant study and granted a waiver or informed consent. Retrospective review was performed or 1701 consecutive nonpalpable microcalcification lesions in 1511 women aged 29-92 years (median age. 54 years) who undewent percutaneous stereotactic biopsy on a prone biopsy table. Biopsy was successively performed with 14-gauge core, 14-gauge vacuum, and 11-gauge vacuum devices, with mild selection bias, and for each lesion. biopsy was performed with one device. Radiographs of the specimen were obtained to see whether microcalcifications were retrieved. Patient, mammographic, and biopsy variables were correlated with negative radiographs of the specimen. At repeat biopsy or mammographic follow-up. outcome was evaluated in patients with benign histologic results and negative radiographs of the specimen by using Fisher exact test P values. Results: Radiographs of the specimen were negative in 16% (30 of 182) of lesions at 14-gauge core biopsy, in 4% (four of 96) of lesions at 14-gauge vacuum biopsy, and in 1% (19 of 1423) or lesions at 11-gauge vacuum biopsy (P < .001). Substantial bleeding was a significant factor (P < .001) in failure to retrieve microcalcifications at only 11-gauge vacuum biopsy. Histologic results in 53 lesions with negative radiographs of the specimen were malignant (n = 6), indicated atypical hyperplasia (n = 6). or were benign (n = 41). Follow-up in patients with 40 benign lesions was performed with repeat biopsy (n = 17, with malignancy in three lesions) or mammography (n = 23) for 15-128 months (median, 70 months); one patient with one lesion was lost to follow-up. Conclusion: Failure to retrieve microcalcifications was least common with 11-gauge directional vacuum-assisted biopsy and occurred in 1% (19 or 1423) of lesions. Cancer was missed in 8% (three of 40) or benign lesions in patients who were followed up.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据