4.6 Article

Geotextile tube assessment using a hanging bag test

期刊

GEOTEXTILES AND GEOMEMBRANES
卷 24, 期 2, 页码 129-137

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.geotexmem.2005.02.006

关键词

geotextile tube; geotextile; permeability; flow rate; soil retention; hanging bag test

向作者/读者索取更多资源

This paper describes the field performance of three geotextile tube case histories contrasted to the results from 12 hanging bag tests (four different geotextiles at each site). The geotextile tubes were used in three different applications: (i) shoreline protection using a sand infill, (ii) dewatering of dredged harbor sediment, and (iii) dewatering of lagooned industrial ash. The hanging bag test (or HBT) was used as a comparative assessment method. Each of the site soils were used with four different geotextiles commonly used in geotextile tube fabrication. In all cases, the properties of the geotextiles and the soils are contrasted against the overall performance of the particular geotextile used for the tubes. The field performance of the geotextile tubes was mixed. One site performed well, the second fair, and the third poor. Findings presented in this paper show that the hanging bag test is a reasonable predictor of actual field performance. However, the test results do not correlate well with the opening size characteristics of the fabrics. It is hoped that this work will lead to the development of' a standard test method that can be used by engineers to select or approve fabrics for optimal geotextile tube field performance. (c) 2005 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据