4.2 Article

Aflatoxin M1 in milk by immunoaffinity column cleanup with TLC/HPLC determination

期刊

BRAZILIAN JOURNAL OF MICROBIOLOGY
卷 37, 期 2, 页码 164-167

出版社

SOC BRASILEIRA MICROBIOLOGIA
DOI: 10.1590/S1517-83822006000200013

关键词

milk; aflatoxin M-1; thin layer chromatography; immunoaffinity column

向作者/读者索取更多资源

During 2002 and 2003, a total of 107 samples of raw, pasteurized and ultrahigh treated temperature (UHT) milk commercialized in the cities of Sao Paulo and Marilia (SP) were analyzed for the presence of aflatoxin M-1 (AFM(1)). AFM1 was detected in 79 (73.8%) of milk samples, ranging from < 0.02 to 0.26 mu g/L. The samples were analyzed using an immunoaffinity column for cleanup and a thin layer chromatography for determining AFM1. The parameters, such as recovery, repeatibility, detection and quantification limit were evaluated to optimize this method (in-house). Based on spiked samples, the recovery values ranged from 85.83 to 73.86% at levels of 0.010-0.50 mu g/L, respectively, and the relative standard deviation for repeatibility ranged from 7.73 to 2.08%. The quantification limit was 0.02 mu g/L. The results of some samples analyzed by this method demonstrated a satisfatory correlation when compared with High Performance Liquid Chromatography (HPLC). In conclusion, immunoaffinity column cleanup gave excellent results for recovery, sensibility and sample through put. Despite the high rate of occurrence of AFM(1) in samples in both cities, the contamination level could not be considered a serious public health hazard, according to Brazilian legislation.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据