4.6 Article

Development and validation of an HPLC method for the determination of gatifloxacin stability in human plasma

期刊

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.jpba.2005.09.026

关键词

gatifloxacin; stability; HPLC; ciprofloxacin

向作者/读者索取更多资源

A simple reversed-phase high performance liquid chromatography (HPLC) method for the determination of gatifloxacin stability in human plasma was developed and validated. Using ciprofloxacin as an internal standard (IS), separation was achieved on X Terra MS C-18 (3 mm x 50 mm, 5 mu m) column. The mobile phase, 0.025 M disodium hydrogen phosphate (pH 3.0) and acetonitrile (80:20 v/v), were delivered at a flow rate of 1.0 ml/min. The eluent was monitored using spectrophotometeric detection at 293 nm. Plasma samples were deproteinized using Amicon Centrifree system. No interference in blank plastma or of commonly used drugs was observed. The relationship between gatifloxacin concentration and peak height ratio of gatifloxacin to the IS was linear over the range of 0.10-6.0 mu g/ml. The intra-day and inter-day coefficients of variation were <= 2.77 and <= 4.59%, respectively. The extraction recovery of gatifloxacin and the IS from plasma samples was >= 85%. Gatifloxacin was found to be stable for at least 5 h at RT, 7 weeks at -20 degrees C, and after 3 freeze-thaw cycles in plasma 16 h at RT and 48 h at -20 degrees C in deproteinized plasma; and 24 h at RT and 7 weeks at -20 degrees C in phosphate buffer. (c) 2005 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据