4.3 Article

Inappropriate Medication Administration Practices in Canadian Adult ICUs: A Multicenter, Cross-Sectional Observational Study

期刊

ANNALS OF PHARMACOTHERAPY
卷 47, 期 5, 页码 637-643

出版社

SAGE PUBLICATIONS INC
DOI: 10.1345/aph.1R414

关键词

-

资金

  1. Canadian Society of Hospital Pharmacists
  2. Canadian Patient Safety Institute
  3. Canadian Institutes of Health Research
  4. Fonds de la Recherche en Sante du Quebec

向作者/读者索取更多资源

BACKGROUND: Critically ill patients often receive multiple medications via continuous intravenous infusion. Coadministration of multiple medications through the same port of a venous access device often is necessary but requires an assessment of compatibility. OBJECTIVE: To describe the frequency of inappropriate coadministration of continuously infused medications via a Y-site and the use of intravenous catheters in patients in Canadian intensive care units (ICUs) in a multicenter, cross-sectional observational study. METHODS: Data pertaining to medication compatibility via Y-site infusion (medication combinations known to be incompatible or not known to be compatible), frequency of specific medications administered via continuous infusion, and catheter use (median number, location, and types of venous catheters) were collected from medical records of 434 patients in the ICUs of 13 teaching hospitals in Canada. RESULTS: Forty-six percent of patients were receiving 2 or more medication infusions simultaneously. Forty episodes of inappropriate coadministration of these infusions were identified in 37 patients. The prevalence of inappropriate coadministration of drugs via a Y-site port in all patients was 8.5% (95% CI 5.8-11.2). The prevalence of incompatible combinations via Y-site in patients with 2 or more medication infusions was 18.7%. Twenty-five of these 37 patients could have had their drug schedules rearranged into acceptable combinations, leaving 12 patients who would have required additional intravenous access to facilitate appropriate medication infusions. Median (range) number of central and peripheral venous access devices inserted per patient were 1 (0-4) and 1 (0-5), respectively. Seventeen of 95 patients with 2 or more central venous catheters could have had their medication infusions rearranged to render 1 catheter idle. CONCLUSIONS: Inappropriate Y-site combinations of medications continuously infused in Canadian ICUs are common. Management of medication infusions could, however, have been optimized in most of these situations.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据