期刊
CLINICAL MICROBIOLOGY AND INFECTION
卷 12, 期 5, 页码 463-469出版社
ELSEVIER SCI LTD
DOI: 10.1111/j.1469-0691.2006.01370.x
关键词
diagnosis; genital herpes; herpes simplex virus; IgG type-specific serology; IgM tests; seroconversion
资金
- NIAID NIH HHS [AI 30731] Funding Source: Medline
Novel tests (BioPlex) for herpes simplex virus-1 (HSV-1) and HSV-2 IgG were compared with HerpeSelect HSV-1 and HSV-2 ELISAs for type-specific IgG. The sensitivity and specificity of BioPlex HSV-1 IgG were 94% (84/89) and 96% (119/124), respectively, with unselected sera, while the sensitivity and specificity of BioPlex HSV-2 IgG were 92% (109/118) and 98% (95/97), respectively. BioPlex IgM was compared with Diamedix IgM against sera from patients with culture-documented genital herpes. The test results were concordant in 81% of sera from HSV-1 patients and in 90% of sera from HSV-2 patients. Use of BioPlex IgM in addition to BioPlex IgG tests increased HSV-2 seroconversion detection from 47% of subjects to 70%. Use of Diamedix IgM in addition to Focus IgG ELISA increased HSV-2 detection from 40% of subjects to 70%. IgM was detected by BioPlex in 63% of sera from patients with early HSV-2 infection (< 30 days) and in 59% of sera by Diamedix. IgM was also detected in a large proportion of sera from subjects with established HSV-2 infection (33% by BioPlex and 29% by Diamedix). Addition of IgM testing substantially increased the ability to detect seroconversion early in infection. IgM is an indicator of recent infection only in subjects who lack detectable IgG.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐