4.5 Article

Biodegradable implantable fluconazole delivery rods designed for the treatment of fungal osteomyelitis: Influence of gamma sterilization

期刊

出版社

WILEY-LISS
DOI: 10.1002/jbm.a.30657

关键词

fluconazole; biodegradable polymer rods; intrabone marrow delivery systems; osteomyelitis; sterilization

向作者/读者索取更多资源

Fluconazole poly(D,L-lactic) acid (PLA) and poly(L-lactic) acid (L-PLA) implantable delivery rods were studied, in vitro and in vivo, as an alternative treatment of fungal osteomyelitis. Implantable rods loaded with 5% fluconazole (FLU) were prepared by the injection-molding method and sterilized by gamma-irradiation at a dose of 25 kGy. Loading efficiency, physical chemistry (high performance liquid chromatography, X-ray diffraction, gel permeation chromatography), and in vitro and in vivo release assays were performed to evaluate the novel delivery systems and the sterilization effect on implant characteristics. In spite of polymer degradation after gamma-irradiation, the loading efficiency, chemical stability, and crystallographic structure of FLU were not affected. In vivo studies were carried out in femoral bone marrow of rabbits. Approximately 85 and 80% of the total dose were released within 12 and 4 weeks from PLA and L-PLA rods, respectively. This showed a faster release rate of FLU in vivo than in vitro, showing almost zero-order kinetics from PLA rods. (c) 2006 Wiley Periodicals, Inc.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据