4.8 Article

In situ determination of solidosity profiles during activated sludge electrodewatering

期刊

WATER RESEARCH
卷 40, 期 11, 页码 2135-2142

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.watres.2006.04.003

关键词

radiotracer; magnetic resonance imaging; solid-liquid separation; filtration; electroosmosis

向作者/读者索取更多资源

Two non-invasive techniques were evaluated for the on-line measurement of sludge solidosity profiles during both pressure and electrodewatering operations. In a first approach, a radioactive tracer adsorbed onto the sludge solids was monitored by a gamma camera. Although this technique appeared very flexible in use, the lack of resolution highly limited its usefulness for (electro)dewatering experiments. Improvement in gamma camera resolution by the development of new detectors might, however, increase the future applicability of this technique. In a second technique, nuclear magnetic resonance measurements on a specially designed electrodewatering unit were made. Hereby, reliable on-line measurements of the solidosity profiles of activated sludge during electrodewatering could be made, with a resolution of less than 1mm. Thus, the mechanisms of electroosmotic- and pressuredriven cake dewatering could be illustrated. Given the measurement time required for measuring one sludge profile, both techniques appeared mainly suited for slowly varying processes, such as activated sludge expression, and not for fast changing processes, such as the initial phases of sludge filtration. (c) 2006 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据