4.5 Article

Heterogeneous three-dimensional anatomical and electrophysiological model of human atria

出版社

ROYAL SOC
DOI: 10.1098/rsta.2006.1781

关键词

simulation; sinoatrial node; human; atrium; anisotropic excitation conduction; visible female dataset

向作者/读者索取更多资源

Investigating the mechanisms underlying the genesis and conduction of electrical excitation in the atria at physiological and pathological states is of great importance. To provide knowledge concerning the mechanisms of excitation, we constructed a biophysical detailed and anatomically accurate computer model of human atria that incorporates both structural and electrophysiological heterogeneities. The three-dimensional geometry was extracted from the visible female dataset. The sinoatrial node (SAN) and atrium, including crista terminalis (CT), pectinate muscles (PM), appendages (APG) and Bachmann's bundle (BB) were segmented in this work. Fibre orientation in CT, PM and BB was set to local longitudinal direction. Descriptions for all used cell types were based on modifications of the Courtemanche et al. model of a human atrial cell. Maximum conductances of I-to, I-Kr and I-Ca,I-L were modified for PM, CT, APG and atrioventricular ring to reproduce measured action potentials (AP). Pacemaker activity in the human SAN was reproduced by removing I-K1, but including I-f, I-Ca,I-T, and gradients of channel conductances as described in previous studies for heterogeneous rabbit SAN. Anisotropic conduction was computed with a monodomain model using the finite element method. The transversal to longitudinal ratio of conductivity for PM, CT and BB was 1 : 9. Atrial working myocardium (AWM) was set to be isotropic. Simulation of atrial electrophysiology showed initiation of APs in the SAN centre. The excitation spread afterwards to the periphery near to the region of the CT and preferentially towards the atrioventricular region. The excitation extends over the right atrium along PM. Both CT and PM activated the right AWM. Earliest activation of the left atrium was through BB and excitation spread over to the APG. The conduction velocities were 0.6 m s(-1) for AWM, 1.2 m s(-1) for CT, 1.6 m s(-1) for PM and 1.1 m s(-1) for BB at a rate of 63 bpm. The simulations revealed that bundles form dominant pathways for atrial conduction. The preferential conduction towards CT and along PM is comparable with clinical mapping. Repolarization is more homogeneous than excitation due to the heterogeneous distribution of electrophysiological properties and hence the action potential duration.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据