4.5 Article

In vivo temperature profile of intervertebral discs and vertebral endplates during vertebroplasty -: An experimental study in sheep

期刊

SPINE
卷 31, 期 15, 页码 1674-1678

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/01.brs.0000224193.52587.d8

关键词

vertebroplasty; PMMA; bone cement; temperature; thermal necrosis; sheep

向作者/读者索取更多资源

Study Design. Experimental study of temperature profiles during vertebroplasty. Objectives. To define accurate temperature profiles during vertebroplasty in an in vivo animal model. Summary of Background Data. Controversy still exists whether vertebroplasty achieves its analgesic effect by stabilizing fracture fragments or due to thermal damage of sensory nerves inside the vertebral body. Furthermore, the energy release during cement polymerization may cause thermal injury to the spinal cord or intervertebral discs. Methods. A total of 4.0 mL PMMA was injected into three lumbar vertebrae of four skeletally mature mixed-bred ewes. Nine separate K-type thermocouples were placed into 12 vertebrae and their adjacent intervertebral discs. Temperature changes were recorded continuously before, during, and after the injection. Results. The highest peak temperatures were measured at the cranial endplate (mean 42.4 +/- 8.8 C) and in the center of the vertebral body (mean 43.3 +/- 6.9 C). Temperatures stayed above 40 C for approximately 2.5 minutes. Peak temperatures in the discs and at the dorsal wall (closest to spinal cord) did not exceed 41 C and 47 C and stayed above 40 C for approximately 1.5 minutes. Conclusions. The intervertebral discs and the spinal cord do not seem to be in danger of thermal damage during vertebroplasty. The measured energy does not seem to be sufficient for the palliative effect achieved by vertebroplasty.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据