4.7 Article

Chemical characterization of odors due to some industrial and urban facilities in Izmir, Turkey

期刊

ATMOSPHERIC ENVIRONMENT
卷 40, 期 22, 页码 4210-4219

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.atmosenv.2005.12.067

关键词

odor concentration; olfactometry; GC-MS; rendering plan; sanitary landfill; petroleum industry

向作者/读者索取更多资源

The relationship between odor concentrations (olfactometry) and chemical concentrations (gas chromatography-mass spectrometry, GC-MS) was studied for the odorous air compositions of a rendering plant, a sanitary landfill and an industrial area with large petroleum and petrochemical industries. Samples taken from the university campus located in a non-industrial and non-urban area were also studied for several organic components for comparison. Ambient air samples were taken into special bags by using an odor sampling device designed for field sampling of odors. In the laboratory odorous chemicals in the samples were transferred into adsorbent tubes and analyzed using a combination of thermal desorption and GGMS. Results point to different characteristics of the odorous gases and air in and around the urban and industrial sources. Among the 64 specific compounds studied, 49 volatile organic compounds (VOCs) were detected in rendering plant, 53 VOCs were detected in sanitary landfill and 44 VOCs were detected in petroleum and petrochemical industries. The compounds measured in the odorous gas composition are the alkanes, alkenes, carbonyls, arenes, chlorinated and other halogenated compounds and organic chlorides as well as the volatile fatty acids. (c) 2006 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据