4.7 Article

Effects of cleaning procedures of silica wafers on their friction characteristics

期刊

JOURNAL OF COLLOID AND INTERFACE SCIENCE
卷 299, 期 1, 页码 233-237

出版社

ACADEMIC PRESS INC ELSEVIER SCIENCE
DOI: 10.1016/j.jcis.2006.01.044

关键词

friction; AFM; silica; surface cleaning; hydrophilic surface

向作者/读者索取更多资源

Silicon wafers with thermal silicon oxide layers were cleaned and hydrophilized by three different methods: (1) the remote chemical analysis (RCA) wet cleaning by use of ammonia and hydrogen peroxide mixture solutions, (2) water-vapor plasma cleaning, and (3) UV/ozone combined cleaning. All procedures were found to remove effectively organic contaminations on wafers and gave identical characteristics of the contact angle, the surface roughness and the normal force interactions, measured by atomic force microscopy (AFM). However, it is found that wafers cleaned by the RCA method have several times larger friction coefficients than those cleaned by the plasma and UV/ozone methods. The difference was explained by the atomic-scale topological difference induced during the RCA cleaning. This study reveals the lateral force microscopy as a very sensitive method to detect the microstructure of surfaces. (c) 2006 Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据