4.8 Article

Considerations on ultra-trace analysis of phthalates in drinking water

期刊

WATER RESEARCH
卷 40, 期 13, 页码 2572-2582

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.watres.2006.05.002

关键词

stir bar sorptive extraction; liquid desorption; large volume injection; capillary GC-MS; phthalate esters; international regulatory directives; contamination profile; trace analysis; drinking water matrices

向作者/读者索取更多资源

Stir bar sorptive extraction with liquid desorption followed by large volume injection and capillary gas chromatography coupled to mass spectrometry (SBSE-LD/LVI-GC-MS), had been applied for the determination of ultra-traces of seven-phthalates (dimethyl phthalate, diethyl phthalate, di-n-butyl phthalate, butyl benzyl phthalate, bis(2-ethylhexyl) adipate, bis(2-ethylhexyl) phthalate and bis(l-octyl) phthalate) in drinking water samples, which are included in the priority lists set by several international regulatory organizations. instrumental calibration under the selected-ion monitoring mode acquisition (LVI-GC-MS(SIM)), experimental parameters that could affect the SBSE-LD efficiency, as well as, the control of the contamination profile are fully discussed. Throughout systematic assays on 30 mL water samples spiked at the 0.40 mu g/L level, it had been established that stir bars coated with 47 mu L of polydimethylsiloxane, an equilibrium time of 60 min (1000 rpm) and methanol as back extraction solvent, allowed the best analytical performance to monitor phthalates in water matrices. From the data obtained, good accuracy and a remarkable reproducibility (< 14.8%) were attained, providing experimental recovery data in agreement with the theoretical equilibrium described by the octanol-water partition coefficients (K-PDMS/W approximate to K-O/W), with the exception of bis(2-ethylhexyl) adipate, bis(2-ethylhexyl) phthalate and bis(I-octyl) phthalate, for which lower yields were measured. Additionally, a remarkable linear dynamic range between 25 and 2000 ng/L (r(2) > 0.99), and low detection limits (3-40 ng/L) were also achieved for the seven-phthalates studied. The application of the present method to monitor phthalates in tap and bottled mineral water samples, allowed convenient selectivity and high sensitivity up to 1.0 mu g/L level, using the standard addition methodology. The proposed method showed to be feasible and sensitive with a low sample volume requirement to monitor phthalates in drinking water matrices at the ultra-trace level, in compliance with international regulatory directives on water quality. (c) 2006 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据