期刊
JOURNAL OF MEMBRANE SCIENCE
卷 278, 期 1-2, 页码 232-238出版社
ELSEVIER SCIENCE BV
DOI: 10.1016/j.memsci.2005.11.006
关键词
biologically treated sewage effluent; effluent organic matter; fraction; fouling; hydrophobic; hydrophilic; membrane characterization; transphilic; ultrafiltration
Membrane fouling caused by hydrophobic (HP), transphilic (TP), and hydrophilic (HL) fractions in biologically treated sewage effluent (BTSE) are still not well understood. Some researches reported that the HP fraction (humic substances) were the major problem; other studies indicated that the HL fraction (polysacchrides) were the main causes for severe fouling in membrane filtration. Hence, in this study, a detailed ultrafilter experiments were conducted with the HP, TP, and HL fractions to study the membrane fouling. The ultrafiltration (UF) removed 67.4%, 52.9%, and 19.7% of HP, TP, and HL fractions, respectively. High removal of the HP fraction is due to relatively high MW of organic matter in the HP fraction and the interaction between the HP fraction and membrane surface. The flux decline with the HP fraction was high compared with the TP and HL fractions. The membrane fouled with different fractions was characterized in terms of functional groups, zeta potential, foulant concentration, and contact angle. (c) 2005 Elsevier B.V. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐