4.7 Article

Active health monitoring in a rotating cracked shaft using active magnetic bearings as force actuators

期刊

JOURNAL OF SOUND AND VIBRATION
卷 294, 期 3, 页码 454-465

出版社

ACADEMIC PRESS LTD- ELSEVIER SCIENCE LTD
DOI: 10.1016/j.jsv.2005.11.020

关键词

-

向作者/读者索取更多资源

We consider the active health monitoring of rotordynamic systems in the presence of breathing shaft cracks. The shaft is assumed to be supported by conventional bearings and an active magnetic bearing (AMB) is used in a mid-shaft or outboard location as an actuator to apply specified, time-dependent forcing on the system. These forces, if properly chosen, induce a combination resonance that can be used to identify the magnitude of the time-dependent stiffness arising from the breathing mode of the shaft crack. (c) 2006 Elsevier Ltd. All rights reserved.