4.6 Article Proceedings Paper

Automated analysis of 2-methyl-3-furanthiol and 3-mercaptohexyl acetate at ng L-1 level by headspace solid-phase microextracion with on-fibre derivatisation and gas chromatography-negative chemical ionization mass spectrometric determination

期刊

JOURNAL OF CHROMATOGRAPHY A
卷 1121, 期 1, 页码 1-9

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.chroma.2006.04.029

关键词

GC-MS-NCI electron capture; thiols; mercaptans; on-fibre derivatisation; SPME; wine; aroma; flavour

向作者/读者索取更多资源

A fast and automated method for the analysis at ng L-1 level of aroma-powerful polyfunctional thiols has been developed and applied to wine. The sample is just poured in a 20 mL vial and its vapour extracted with a poly(dimethylsiloxane)-divinylbenzene (PDMS-DVB) solid-phase microextraction fibre (65 mu m thickness) previously exposed to vapours of the reactive (pentafluorobenzyl bromide) and of an alkali (tributylamine). The derivatised compounds are subsequently desorbed in the GC system and determined by negative chemical ionization mass spectrometry. The method is fully automated by using a Combi-Pal autosampler conveniently programmed. The analysis takes 50 min, which contrasts to the long and tedious methods previously proposed. The development of an optimal procedure is constrained by the aggressive character of the reagent (towards the fibre and the chromatographic column), its volatility and the quality of the blanks that can be obtained. Therefore, a critical step was fixing in the fibre a safe and repetitive amount of reagent. This was achieved by exposing the fibre (5 min) to the vapours of a water: acetone (9: 1) solution containing 200 mg L-1 of reagent. Under these conditions, the extraction-derivatisation of analytes improves with time and temperature, and the best working conditions are dictated by a compromise between sensitivity, speed and chromatographic performance. Although analytes studied were 2-methyl-3-furanthiol, 4-mercapto-4-methyl-2-pentanone, 3-mercaptohexanol, 2-furanmethanethiol and 3-mercaptohexyl acetate, a good analytical performance could be achieved only for these two last compounds. Both of them can berepetitively (10%< RSD < 20%) determined in wine at concentrations below 0.1 ng L-1. Other aspects considered in the method setup were the oxidation of analytes during the process, and the electron-capture detection (ECD) and MS properties of the pentafluorobenzyl derivatives of different polyfunctional thiols. (c) 2006 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据