4.7 Article

Seismic behavior of confined square CFT columns

期刊

ENGINEERING STRUCTURES
卷 28, 期 10, 页码 1378-1386

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.engstruct.2006.01.015

关键词

buckling; CFT; concrete filled tube; confinement; ductility; energy dissipation; seismic behavior

向作者/读者索取更多资源

The failure of conventional concrete filled tubes (CFT) under seismic loading is typically governed by the inelastic buckling and low cycle fatigue rupture. The second author has proposed to use additional confinement to control or delay the inelastic buckling of the steel tube at the potential plastic hinge zones of CFT members. Following the success of the previous studies on confined concrete filled tubes (CCFT) with circular sections, this paper reports the experimental results on square CCFT columns. One conventional CFT and five CCFT model columns were tested under constant axial load and cyclic lateral forces. Test results validated the concept of CCFT for square sections. Compared with the conventional CFT column model, the CCFT columns exhibited significantly improved seismic performance with large ductility. A design method for the additional confinement to the plastic hinge region was also developed and validated. (c) 2006 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据