4.4 Article

Effects of the self-contained breathing apparatus and fire protective clothing on maximal oxygen uptake

期刊

ERGONOMICS
卷 49, 期 10, 页码 911-920

出版社

TAYLOR & FRANCIS LTD
DOI: 10.1080/00140130600667451

关键词

firefighting; personal protective equipment; VO2max test; tidal volume; gas exchange; self-contained breathing apparatus

向作者/读者索取更多资源

To examine the effects of firefighting personal protective ensemble (PPE) and self-contained breathing apparatus (SCBA) on exercise performance, 12 males completed two randomly ordered, graded exercise treadmill tests (GXTPPE and GXT(PT)). Maximal oxygen consumption (VO2max) during GXTPPE was 17.3% lower than the GXTPT in regular exercise clothing (43.0 +/- 5.7 vs. 52.4 +/- 8.5 ml/kg per min, respectively). The lower VO2max during the PPE condition was significantly related (r = 0.81, p < 0.05) to attenuated peak ventilation (142.8 +/- 18.0 vs. 167.1 +/- 15.61/min), which was attributed to a significant reduction in tidal volume (2.6 +/- 10.4 vs. 3.2 +/- 0.41). Breathing frequency at peak exercise was unchanged (55 +/- 7 vs. 53 +/- 7 breaths/min). The results of this investigation demonstrate that PPE and the SCBA have a negative impact on VO2max. These factors must be considered when evaluating aerobic demands of fire suppression work and the fitness levels of firefighters.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据