4.8 Article Proceedings Paper

Battery condition monitoring (BCM) technologies about lead-acid batteries

期刊

JOURNAL OF POWER SOURCES
卷 158, 期 2, 页码 874-878

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.jpowsour.2005.11.008

关键词

battery condition monitoring; lead-acid batteries; VRLA; state of charge (SOC); direct current resistance (DCR); state of health (SOH)

向作者/读者索取更多资源

A novel battery condition monitoring (BCM) technology for lead-acid batteries has been developed. We have developed a highly reliable SOC monitor that improves the estimated precision of the stored capacity to +/- 5% for both the flooded type and VRLA. A novel SOC estimation algorithm was also developed. The SOC value was obtained by the weighting combination of the values from the SOC-DCR table and the current integration. Kalman Filtering Theory contributed to developing this system. In order to improve the accuracy of the SOC-DCR table, we have derived a theoretical equation for the SOC-DCR relationship. This equation helps to interpolate the data and improve the accuracy of the SOC-DCR table. (c) 2005 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据