期刊
CORROSION SCIENCE
卷 48, 期 9, 页码 2855-2866出版社
PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.corsci.2005.10.005
关键词
metal release; stainless steel; particles; test method; surface area
Data on metal release from stainless steel particles can be used in the assessment and quantification of the potential impact of stainless steel on health and the environment. To elaborate a test method suitable for the study of metal release from particles, the experimental parameters particle loading, agitation and separation of particles from the solution were investigated through exposure of 316L powder particles in two artificial biological media. The results suggest that a small particle loading, bi-linear shaking and centrifugation for separation of particles from the solution give the most reproducible results. They also show that metal release rates are strongly influenced by the physico-chemical properties of the test medium and the effective surface area of particles during exposure. (c) 2005 Elsevier Ltd. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐