4.6 Article

Assessment of myocardial viability using delayed enhancement magnetic resonance imaging at 3.0 tesla

期刊

INVESTIGATIVE RADIOLOGY
卷 41, 期 9, 页码 661-667

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/01.rli.0000233321.82194.09

关键词

myocardial viability; delayed enhancement; myocardial infarction; high field magnetic resonance imaging; contrast media; 3.0 T

向作者/读者索取更多资源

Objective: Cardiac magnetic resonance imaging (MRI) at 3.0 T has recently become available and potentially provides a significant improvement of tissue contrast in TI-weighted imaging techniques relying on Gd-based contrast enhancement. Imaging at high-field strength may be especially advantageous for methods relying on strong T I-weighting and imaging after contrast material administration. The aim of this study was to compare cardiac delayed enhancement (DE) MRI at 3.0 T and 1.5 T with respect to image quality, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) between infarcted and normal myocardium. Materials and Methods: Forty consecutive patients with history of myocardial infarction were examined at 3.0 T (n = 20) or at 1.5 T (n = 20). Myocardial function was assessed using cine steady-statefree-precession (SSFP) sequences (TR 3.1 milliseconds, TE 1.6 milliseconds, flip angle 70', and a matrix of 168 X 256 at 1.5 T and TR 3.4 milliseconds, TE 1.7 milliseconds, flip angle 50 degrees and a matrix of 168 X 256 at 3.0 T), acquired in long- and short-axes views. DE images were obtained 15 minutes after the administration of 0.15 mmol of Gd-DTPA/kg body weight using a segmented inversion recovery prepared gradient echo sequence at 1.5 T (TR 9.6 milliseconds, TE 4.4 milliseconds, flip angle 25 degrees, matrix 160 X 256, bandwidth 140 Hertz/pixel) and at 3.0 T (TR 9.8 milliseconds, TE 4.3 milliseconds, flip angle 30 degrees, matrix 150 X 256, bandwidth 140 Hertz/pixel). For image analysis, standardized SNR and CNR measurements were performed in infarcted and remote myocardial regions. Two independent observers rated image quality on a 4-point scale (0 = poor image quality,1 = sufficient image quality, 2 good image quality, 3 = excellent image quality). Results: High diagnostic image quality was obtained in all patients. Rating of mean image quality was 2.2 +/- 0.8 at 1.5 T and 2.5 +/- 0.6 at 3.0 T (P = 0.012) for observer I and 2.2 +/- 0.7 at 1.5 T and 2.6 +/- 0.6 at 3.0 T (P = 0.003) for observer 2, respectively. Interobserver agreement was good (K = 0.68 at 1.5 T and 0.78 at 3.0 T). SNR measurements yielded a mean SNR of 37.8 +/- 13.9/22.9 +/- 6.0 in infarcted myocardium (P < 0.001) and 5.6 +/- 2.2/5.9 +/- 2.4 in normal myocardium (P = 0.45) at 3.0 T/1.5 T, respectively. CNR measurements revealed mean values of 32.4 +/- 13.0/16.7 +/- 5.4 (P < 0.001) at 3.0 T/1.5 T, respectively. Conclusions: Delayed enhancement MRI at 3.0 T is feasible and provides superior image quality compared with 1.5 T. Furthermore, using identical contrast doses, increased SNR and CNR values were recorded at 3.0 T.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据