Evaluation of bone quality near metallic implants with and without lotus-type pores for optimal biomaterial design

期刊

MATERIALS TRANSACTIONS
卷 47, 期 9, 页码 2233-2239

出版社

JAPAN INST METALS & MATERIALS
DOI: 10.2320/matertrans.47.2233

关键词

hard tissue; metallic implant; lotus-type porous implant; biological apatite; bone mineral density; texture; microbeam X-ray diffraction; bone quality; stress shielding; elongated pore

向作者/读者索取更多资源

The stress shielding effect often degrades the quality and quantity of bones near implants. Thus, the shape and structure of metallic biomaterials should be optimally designed. A dominant inorganic substance in bones is a biological apatite (BAp) nanocrystal, which basically crystallizes in an anisotropic hexagonal lattice. The BAp c-axis is parallel to elongated collagen fibers. Because the BAp orientation of bones is a possible parameter of bone quality near implants, we used a microbeam X-ray diffractometer system with a beam spot, which had a diameter of 50 or 100 mu m phi, to evaluate the BAp orientation of bones. Two animal models were prepared: (1) a nail model (phi: 3.0 mm, SUS316L), which was used to understand the stress shielding effect in a rabbit tibial marrow cavity, and (2) a model of a lotus-type porous implant (phi: 3.4 mm, mean pore diameter: 170 mu m, SUS304L), which was used to understand the effect of the unidirectional-elongated pore direction in an anisotropic bone tissue of a beagle mandible. The porous implants were implanted so that the pore direction was parallel or perpendicular to the mesiodistal axis of mandible. For the porous implant model, new bone formation strongly depended on the elongated pore direction and the time after implantation. For example, four weeks after implantation, new bone formed in pores of the implants, but the BAp orientation degree in the new bone was more similar to that in the original bone in the elongated pores parallel to the mesiodistal direction than that in the perpendicular pores. These differences in bone formation inside the parallel and perpendicular pores may be closely related to the anisotropy of original bone tissues such as the orientations of collagen fiber, BAp, and blood vessels. The orientation degree of BAp also changed in the nail model. The stress shielding effect decreased the orientation degree of the BAp c-axis in the tibia along the longitudinal axis. Thus, optimal design of metallic biomaterials such as implant shape, pore size, elongated pore direction, etc., should be based on the anisotropy of the bone microstructure.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据