4.8 Article

Electrochemical detection of arsenic(III) using iridium-implanted boron-doped diamond electrodes

期刊

ANALYTICAL CHEMISTRY
卷 78, 期 18, 页码 6291-6298

出版社

AMER CHEMICAL SOC
DOI: 10.1021/ac0519514

关键词

-

向作者/读者索取更多资源

Iridium-modified, boron-doped diamond electrodes fabricated by an ion implantation method have been developed for electrochemical detection of arsenite ( As(III)). Ir+ ions were implanted with an energy of 800 keV and a dose of 10(15) ion cm(-2). An annealing treatment at 850 degrees C for 45 min in H-2 plasma (80 Torr) was required to rearrange metastable diamond produced by an implantation process. Characterization was investigated by SEM, AFM, Raman, and X-ray photoelectron spectroscopy. Cyclic voltammetry and flow injection analysis with amperometric detection were used to study the electrochemical reaction. The electrodes exhibited high catalytic activity toward As( III) oxidation with the detection limit (S/N = 3), sensitivity, and linearity of 20 nM (1.5 ppb), 93 nA mu M-1 cm(-2), and 0.999, respectively. The precision for 10 replicate determinations of 50 mu M As(III) was 4.56% relative standard deviation. The advantageous properties of the electrodes were its inherent stability with a very low background current. The electrode was applicable for analysis of spiked arsenic in tap water containing a significant amount of various ion elements. The results indicate that the metal-implanted method could be promising for controlling the electrochemical properties of diamond electrodes.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据