Direct DNA hybridization at disposable graphite electrodes modified with carbon nanotubes

期刊

ANALYTICAL CHEMISTRY
卷 78, 期 18, 页码 6656-6659

出版社

AMER CHEMICAL SOC
DOI: 10.1021/ac060202z

关键词

-

向作者/读者索取更多资源

The performance of glassy carbon ( GCE) and graphite pencil electrodes (PGE) modified with multiwalled carbon nanotubes (CNTs) are compared, based on the direct electrochemical detection of nucleic acids. This is accomplished by monitoring the differential pulse voltammetry changes of the guanine signal. CNT-modified PGE compares favorably to that of the commonly used CNT-modified GCE owing to the intrinsic improved performance of the supporting PGE. The better intrinsic characteristics of the PGE are related to its composite structure and higher level of porosity compared to GCE. The performance characteristics of the direct DNA hybridization on the disposable CNT-modified PGE are studied in terms of optimum analytical conditions such as probe concentration, target concentration, hybridization time, and selectivity. The new DNA biosensor described here has shown some important advantages such being inexpensive, sensitive, selective, and able to generate reproducible results using a simple and direct electrochemical protocol.