期刊
JOURNAL OF SEPARATION SCIENCE
卷 29, 期 15, 页码 2322-2329出版社
WILEY-V C H VERLAG GMBH
DOI: 10.1002/jssc.200600139
关键词
amphetamines; fluorescence detection; HPLC; SPE procedure; urine
A precise and feasible HPLC method has been developed for the analysis of amphetamine (AMPH), methamphetamine (MAMPH) and methylenedioxymethamphetamine (MDMA, ecstasy) in human urine. A chromatographic run on a C8 Genesis (150 mm x 4.6 mm, 5 mu m) column maintained at 30 degrees C lasts about 17 min, using a mobile phase composed of ACN (12%) and a pH 2.5 phosphate buffer (88%) containing 0.3% triethylamine. Mirtazapine was used as the internal standard. Good linearity was found in the 100-2000 ng/mL concentration range for AMPH and MAMPH and in the 12-2000 ng/mL concentration range for MDMA. The pretreatment of urine samples was carried out by means of a careful SPE procedure on C2 cartridges. The extraction yields were very satisfactory for all analytes, with average values greater than 97%. The leading conditions allowed the determination of AMPH, MAMPH and MDMA with satisfactory precision and accuracy. The method has been successfully applied to the determination of the analytes in urine of AMPH users.