期刊
APPLIED SPECTROSCOPY
卷 60, 期 10, 页码 1181-1187出版社
SAGE PUBLICATIONS INC
DOI: 10.1366/000370206778664572
关键词
laser-induced breakdown spectroscopy; LIBS; glass analysis; laser ablation inductively coupled plasma mass spectrometry; LA-ICP-MS
A comparative analysis of the discriminating power of laser-induced breakdown spectroscopy (LIBS) and laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), each coupled with refractive index (RI) measurements, is presented for a study of 23 samples of automobile float glass. Elemental emission intensity ratios (LIBS) and elemental concentration ratios (LA-ICP-MS) and their associated confidence intervals were calculated for each float glass sample. The ratios and confidence intervals were used to determine the discrimination power of each analytical method. It was possible to discriminate 83% of the glass samples with 99% confidence based on LIBS spectra alone, and 96-99% of the samples could be discriminated based on LIBS spectra taken in conjunction with RI data at the same confidence level. LA-ICP-MS data allowed for 100 % discrimination of the samples without the need for RI data. The results provide evidence to support the use of LIBS combined with RI for forensic analysis of float glass in laboratories that do not have access to LA-ICP-MS.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐