4.7 Article

Diaion SP-850 resin as a new solid phase extractor for preconcentration-separation of trace metal ions in environmental samples

期刊

JOURNAL OF HAZARDOUS MATERIALS
卷 137, 期 3, 页码 1496-1501

出版社

ELSEVIER
DOI: 10.1016/j.jhazmat.2006.04.027

关键词

preconcentration; solid phase extraction; heavy metal; Diaion SP-850; alpha-benzoin oxime; AAS

向作者/读者索取更多资源

A solid phase extraction method was developed for the preconcentration and separation of trace amounts of chromium, manganese, iron, cobalt, copper, cadmium and lead from environmental samples by complexation with alpha-benzoin oxime followed by adsorption onto Diaion SP-850-solid phase extraction column. One molar per liter HNO3 was used as eluent. The recoveries of analytes at pH 8.0 with 700 mg of resin were greater than 95% without interference from alkaline, earth alkaline and some metal ions. The detection limits by three sigma for analyte ions were 0.65 mu g l(-1) for Cr(III), 0.42 mu g l(-1) for Mn(II), 0.28 mu g l(-1) for Fe(III), 0.73 mu g l(-1) for Co(II), 0.30 mu g l(-1) for Cu(II), 0.47 mu g l(-1) for Cd(II) and 0.50 mu g l(-1) for Pb(II). The validation of the procedure was performed by the analysis of the certified standard reference materials. The presented procedure was applied to the determination of analytes in tap, river and sea waters, rice, wheat, canned tomato and coal samples with successfully results (recoveries greater than 95%, R.S.D.'s lower than 8%). (c) 2006 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据