3.9 Article

Airborne virus sampling - Efficiencies of samplers and their detection limits for infectious bursal disease virus (IBDV)

期刊

出版社

INST AGRICULTURAL MEDICINE
DOI: 10.5604/12321966.1120585

关键词

airborne transmission; sampling efficiency; bioaerosol; Gumboro virus

资金

  1. AI-FES budget of the Dutch Ministry of Economic Affairs

向作者/读者索取更多资源

Introduction. The airborne transmission of infectious diseases in livestock production is increasingly receiving research attention. Reliable techniques of air sampling are crucial to underpin the findings of such studies. This study evaluated the physical and biological efficiencies and detection limits of four samplers (Andersen 6-stage impactor, all-glass impinger AGI-30, OMNI-3000 and MD8 with gelatin filter) for collecting aerosols of infectious bursal disease virus (IBDV). Materials and Method. IBDV aerosols mixed with a physical tracer (uranine) were generated in an isolator, and then collected by the bioaerosol samplers. Samplers' physical and biological efficiencies were derived based on the tracer concentration and the virus/tracer ratio, respectively. Detection limits for the samplers were estimated with the obtained efficiency data. Results. Physical efficiencies of the AGI-30 (96%) and the MD8 (100%) were significantly higher than that of the OMNI-3000 (60%). Biological efficiency of the OMNI-3000 (23%) was significantly lower than 100% (P < 0.01), indicating inactivation of airborne virus during sampling. The AGI-30, the Andersen impactor and the MD8 did not significantly inactivate virus during sampling. The 2-min detection limits of the samplers on airborne IBDV were 4.1 log(10) 50% egg infective dose (EID50) m(-3) for the Andersen impactor, 3.3 log(10) EID50 m(-3) for the AGI-30, 2.5 log(10) EID50 m(-3) for the OMNI-3000, and 2.9 log(10) EID50 m(-3) for the MD8. The mean half-life of IBDV aerosolized at 20 degrees C and 70% was 11.9 min. Conclusion. Efficiencies of different samplers vary. Despite its relatively low sampling efficiency, the OMNI-3000 is suitable for use in environments with low viral concentrations because its high flow rate gives a low detection limit. With the 4 samplers investigated, negative air samples cannot guarantee virus-free aerial environments, which means that transmission of infectious agents between farms may still occur even when no virus has been detected.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

3.9
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据