4.7 Article

Macrocell and microcell corrosion of steel in ordinary Portland cement and high performance concretes

期刊

CEMENT AND CONCRETE RESEARCH
卷 36, 期 11, 页码 2098-2102

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.cemconres.2006.07.005

关键词

microcell corrosion; macrocell corrosion; durability; electrochemical properties; high-performance concrete

向作者/读者索取更多资源

Microcell corrosion is the term given to the situation. where active corrosion and the corresponding cathodic half-cell reaction take place at adjacent parts of the same metal. Macrocell corrosion can occur when the actively corroding bar is coupled to another bar which is passive, either because of its different composition or because of different environment. The present study was undertaken to determine the influence of concrete type and properties on the relative microcell and macrocell corrosion rates. The samples were monitored for more than 3 years and the results confirm that microcell corrosion is the major mechanism in corrosion of steel reinforcing bars in concrete. Furthermore, results show that, for high performance concrete, the difference between microcell and macrocell corrosion is far more significant than for ordinary Portland cement concrete because of its high resistance to ionic flow. (c) 2006 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据