Hydroxyapatite (HA) ceramics are used as implants to repair damaged/removed bone, and negative or positive electrical polarization enhances osteoblast and decreases osteoclast activity, respectively, in vivo. We compared the ability of electrically polarized and non-polarized HA with interconnected pores (IPHA) implants to promote bone growth. Polarized or non-treated IPHAs were implanted into the right or left femoral condyle of rabbits (N = 10 in each group), and we performed histological examination, including enzymatic staining for osteoblasts and osteoclasts, 3 and 6 weeks after implantation. We observed improved bone ingrowth and increased osteoblast activity in polarized implants with complete bone penetration into polarized implants occurring as early as 3 weeks after surgery. In contrast, non-polarized implants were not fully ossified at 6 weeks after surgery. Furthermore, positively charged implant regions had decreased osteoclast activity compared to negatively charged or uncharged regions. We propose two different models to explain these observations. (c) 2006 Elsevier Ltd. All rights reserved.