4.1 Article

Targeted ultrasound contrast agent for molecular imaging of inflammation in high-shear flow

期刊

CONTRAST MEDIA & MOLECULAR IMAGING
卷 1, 期 6, 页码 259-266

出版社

WILEY-HINDAWI
DOI: 10.1002/cmmi.113

关键词

microbubbles; targeting; echo contrast; ultrasound contrast; P-selectin; inflammation; ultrasound imaging; sialyl Lewis(X)

资金

  1. NHLBI NIH HHS [HL64381, HL07284] Funding Source: Medline
  2. NIBIB NIH HHS [EB002185] Funding Source: Medline
  3. NIDDK NIH HHS [DK63508] Funding Source: Medline

向作者/读者索取更多资源

Targeted ultrasound contrast materials (gas-filled microbubbles carrying ligands to endothelial selectins or integrins) have been investigated as potential molecular imaging agents. Such microbubbles normally exhibit good targeting capability at the slower flow conditions. However, in the conditions of vigorous flow, binding may be limited. Here, we describe a microbubble capable of efficient binding to targets both in slow and fast flow (exceeding 4 dyne/cm(2) wall shear stress) using a clustered polymeric form of the fast-binding selectin ligand sialyl Lewis(X). Microbubbles were prepared from decafluorobutane gas and stabilized with a monolayer of phosphatidylcholine, PEG stearate and biotin-PEG-lipid. Biotinylated PSLe(x) (sialyl Lewis(x) polyacrylamide) or biotinylated anti-P-selectin antibody (RB40.34) was attached to microbubbles via a streptavidin bridge. In a parallel plate flow chamber targeted adhesion model, PSLe(x) bubbles demonstrated specific adhesion, retention and slow rolling on P-selectin-coated plates. Efficiency of firm targeted adhesion to a P-selectin surface (140 molecules/mu m(2)) was comparable for antibody-carrying bubbles and PSLe(x)-targeted bubbles at 0.68 dyne/cm(2) shear stress. At fast flow (4.45 dyne/cm(2)), PSLe(x)-targeted bubbles maintained their ability to bind, while antibody-mediated targeting dropped more than 20-fold. At lower surface density of P-selectin (7 molecules/mu m(2)), targeting via PSLe(x) was more efficient than via antibody under all the flow conditions tested. Negative control casein-coated plates did not retain bubbles in the range of flow conditions studied. To confirm echogenicity, targeted PSLe(x)-bubbles were visualized on P-selectin-coated polystyrene plates by ultrasound imaging with a clinical scanner operated in pulse inversion mode; control plates lacking targeted bubbles did not show significant acoustic backscatter. In vivo, in a murine model of inflammation in the femoral vein setting, targeting efficacy of intravenously administered PSLe(x)-microbubbles was comparable with targeting mediated by anti-P-selectin antibody, and significantly exceeded the accumulation of non-targeted control bubbles. In the inflamed femoral artery setting, PSLe(x)-mediated microbubble targeting was superior to antibody-mediated targeting. Copyright (C) 2006 John Wiley & Sons, Ltd.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.1
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据